About this site 한국어

Unofficial explanatory translation of the Korean AI-Ready Data (AIRD) draft standard. The Korean text prevails.

Preparing data › Procedure

Reading the diagnostic report (stage 2)

Type · ProcedureReading time · about 4 minData providers

ContentsContents
  1. Structure of the diagnostic report
  2. Diagnostic Maturity by data type
  3. Quality tier and readiness state
  4. Sorting indicators that were not measured

This page shows how to tell measured indicators from indicators that were not measured in the diagnostic report produced by the diagnostic tool, and how to choose the next action for each indicator that was not measured.

GoalSeparate what was measured from what was not measured in the diagnostic report, and find why each indicator was not measured and what material it needs.

This site does not accept files for diagnosis. The release version of the diagnostic tool is in development; the release plan is in Development status and upcoming releases. Actual measurement results are in Public data examples and Walkthrough with example data.

Structure of the diagnostic report

The diagnostic report records six values separately. The data provider reads them in order, from the top.

ValueQuestion it answersForm of the valueDecided by
Indicator applicabilityWas the indicator measured?APPLIED · PARTIALLY_APPLIED · PRECONDITION_UNMET · NOT_APPLICABLE · OPTIONAL_SKIPPEDStandard
Indicator scoreWhat is the value of a measured indicator?From 0 to 1Standard (measurement formula)
Reason for not measuringWhy was it not measured?A sentence stating the reason, recorded with the applicability valueStandard
Diagnostic Maturity (DM)How far were the required indicators measured?DM-0 · DM-1 · DM-2 · not judgedDecision table (standard) · the lower bound for DM-1 is set by the operating guideline
Quality tierWhat level is the measured quality?Tier 0–4 · not judgedThreshold profile of the operating guideline — not judged if none is applied
Readiness stateWhat state is the data in?Discoverable · Quality-Ready · Purpose-ReadyTransition judgment at the decision gate [Part 1 5.2]

Scores and Diagnostic Maturity do not substitute for each other. If Diagnostic Maturity is not DM-2, the quality tier is “not judged: below DM-2” however high the scores are. The Diagnostic Maturity decision table is in Judgment procedure. The meaning of each indicator applicability value and what the data provider does for it are in Measuring quality (stage 2).

Diagnostic Maturity by data type

The Diagnostic Maturity reached without an operating guideline differs by data type. The indicators that block Diagnostic Maturity and the material the data provider must prepare also differ by type. The table below shows the results of measuring the cleaned versions of the public data examples.

ExampleDiagnostic Maturity (cleaned version)Blocking indicatorWhat is needed
STRUCT × KGDM-0 (provisional) Under reviewD5-03 (Statistical plausibility) — dummy-value patterns set by the operating guideline · D2-02 (Referential integrity) partially measuredOperating guideline · code table values (D2-02)
TSERIES × StatsDM-0 (provisional) Under reviewD5-03 — dummy-value patterns set by the operating guidelineOperating guideline
TEXT × RAGDM-2None—
PT × FineTuningDM-0D3-02 (Label accuracy) — expert review results are an inputA ground-truth set reviewed by experts
IMAGE (no example)—D3-02 — expert review results are an inputA ground-truth set reviewed by experts · label-match criteria (indicator parameters in the operating guideline)

The Diagnostic Maturity of the tabular (STRUCT) and time series (TSERIES) examples is a provisional value, with D5-03 measured using the example patterns in Part 2 Appendix I. Results measured with the example patterns are being checked against the standard text.

DM-1 does not appear in the four examples. DM-1 is judged by whether evaluation coverage is at or above the lower bound in the operating guideline. Without an operating guideline, DM-1 is not judged. A result that measured every minimum measurable indicator (MMI) but did not reach DM-2 is therefore DM-0.

The document (TEXT) example reaches DM-2 even without an operating guideline. D5-03 does not apply to the document type. The diagnostic tool measured all five required formal indicators for the document type. With an operating guideline applied, the quality tier of the document example can be judged.

The row-by-row conditions of the decision table are in Judgment procedure.

Quality tier and readiness state

The quality tier of all four examples is “not judged: no operating guideline applied.” This includes the document example, whose Diagnostic Maturity is DM-2. The quality tier is judged with the threshold profile of an operating guideline. This site does not assign tiers with the example threshold profile (status EXAMPLE).

The operating guideline provided with the standard will be published when the standard is established (expected December 2026). Organizations and institutions can build their own operating guideline and judge quality tiers. Whoever judges a tier records the operating guideline’s identifier and version with the tier and publishes the operating guideline it applied. How to build an operating guideline is in Building an operating guideline.

The readiness state of all four examples stays at Discoverable. A transition to Quality-Ready requires all three of the following conditions.

  • Diagnostic Maturity DM-2
  • Quality tier Tier 1 or higher
  • An operating guideline applied

Even an example with a manifest, a diagnostic report, a processing history and purpose-specific operation files gets a quality tier only when an operating guideline is applied. The Quality-Ready transition can be judged only once there is a quality tier. [Part 1 5.1]

Sorting indicators that were not measured

The data provider sorts the indicators that were not measured into three groups by the material they need.

GroupMeaningExample
Can be done nowNo additional material neededDesignating a record key · entering metadata elements
Can be done after obtaining materialThe material to obtain and the indicators it makes measurableCode table → D2-02 (Referential integrity) · D3-01 (Standard name conformance)
Outside the data provider’s scopeRecord the reason and waitApplying an operating guideline → tier judgment

Completion criteria

  • Distinguish the six values in the diagnostic report (indicator applicability · indicator score · reason for not measuring · Diagnostic Maturity · quality tier · readiness state)
  • Identify the indicators that block Diagnostic Maturity and their reasons
  • Sort the indicators that were not measured into three groups (can be done now · can be done after obtaining material · outside the data provider’s scope)

What you need The diagnostic report for your own data is produced by the diagnostic tool. The release version of the diagnostic tool is in development. Until then, you can learn how to read a report from the measurement results in Public data examples.

Last updated · 2026-10-07Report an error