About this site 한국어

Unofficial explanatory translation of the Korean AI-Ready Data (AIRD) draft standard. The Korean text prevails.

Operating guidelines

Building an operating guideline

Type · ProcedureReading time · about 4 minAdopting and operating organizationsOrganizations that buy or procure data

ContentsContents
  1. Roles of the operating guideline and the standard
  2. Same scores, different thresholds
  3. Ways to build an operating guideline
  4. Structure of the threshold profile
  5. Tier labels and publication requirements
  6. Example threshold profile (Part 2 Appendix I)
  7. Purpose-specific criteria
  8. Measurement before an operating guideline is applied

An operating guideline is a document that holds judgment threshold values and operational matters, built separately from the standard. The tier system, tier names, label format and judgment procedure follow the standard; threshold values and operational matters are set by the operating guideline.

Roles of the operating guideline and the standard

The numbers used for judgment (the threshold profile) and operational matters such as the diagnosis cycle and result validity period are set by the operating guideline; tier elements such as the tier system, judgment procedure, quality indicator definitions and tier label format are specified by the standard.

List of operational and tier elements

Each column is a separate list; items on the same row are not paired.

Set by the operating guideline (operational elements)Specified by the standard (tier elements)
Tier band boundaries in the threshold profileTier scheme Tier 0–4 and tier names (Unqualified · Bronze · Silver · Gold · Platinum) [Part 2 7.1]
Per-dimension required pass lines, dimension weights, and weight adjustment ranges in the threshold profileJudgment procedure: candidate tier from the minimum dimension score → pass line check → demotion by one tier if any dimension falls short [Part 2 6 · 7]
DM-1 evaluation coverage lower bound and indicator parameters (D3-02 (label accuracy) label match criterion · D5-03 dummy value patterns) in the threshold profileDefinitions, measurement formulas, and the Diagnostic Maturity decision table for the 16 quality indicators [Part 2 Annex B.5]
Identifier, version, and activation procedure of the threshold profileElement structure of the threshold profile [Part 2 Annex D · Table 9-3]
Operational matters: diagnosis cycle · result validity period · appeal procedure · tool certification [Part 1 7.1]Tier label format Gold (Tier 3, STRUCT) [Part 1 Annex A]
Judgment criteria for purpose tiers · detailed pack structureReadiness states and pack composition [Part 1 5.1 · 5.5]

Same scores, different thresholds

The same dimension scores can yield different quality tiers depending on the threshold values of the applied operating guideline. The thresholds in the simulation below are hypothetical values generated at random; they are not values proposed by this site.

Ways to build an operating guideline

The standard-provided operating guideline is published when the standard is established (expected December 2026). There is more than one guideline publisher: organizations, institutions and domains can build operating guidelines independently. A guideline publisher chooses one of the following three approaches.

  • Adopt: apply the standard-provided operating guideline as is, and state that guideline’s identifier and version with the tier.
  • Adjust: adjust the threshold profile and operational matters based on the standard-provided operating guideline, and publish the adjusted guideline under your own identifier and version.
  • Build your own: set the threshold profile and operational matters directly, and publish the guideline under your own identifier and version.

In every approach, tier elements follow the standard.

Structure of the threshold profile

The threshold profile (judgment threshold values) is a machine-readable file within the operating guideline. It holds the numbers adjusted during operation, such as tier bands, pass lines and weights, with an identifier and a version. The operating guideline sets the identifier, version and activation procedure; Part 2 Annex D specifies the structure of the elements. The machine representation is aird-threshold-profile-1.0.schema.json.

Threshold profile elements — expand table (10 rows)
ElementObligationValue rangeValue it sets
profileIdRequiredURIProfile identifier
versionRequiredSemVerProfile version
statusRequiredOFFICIAL or EXAMPLEProfile status
digestRequiredSHA-256Hash of the profile file
tierThresholdsRequired4 values in 0.0–1.0Tier bands (Part 2 7.1)
passLinesRequired7 dimensions × 4 tiersPer-dimension required pass lines (7.2)
dimensionWeightsRequired7 values summing to 1.00Dimension weights (6.3)
weightAdjustmentRangeRequiredLower and upper bound per dimensionWeight adjustment range (6.3)
dm1CoverageRequired0.0–1.0DM-1 evaluation coverage lower bound (8.1)
indicatorParametersConditionally requiredObject per indicatorD3-02 image label match criterion · D5-03 dummy value patterns

Tier labels and publication requirements

Whoever judges and publishes tiers observes the following four requirements.

  • Tier label in the standard format: write the tier in the form Gold (Tier 3, STRUCT). The data type must always be included; Diagnostic Maturity (DM) is left out of the tier label.
  • Operating guideline identifier and version alongside: state the identifier and version of the operating guideline applied in the judgment together with the tier.
  • Publication of the operating guideline and threshold profile: publish the applied operating guideline and threshold profile so that anyone can access them.
  • Hash record: record the identifier, version and hash of the threshold profile in the diagnostic report. Data users can use the hash to verify the file used in the judgment.

Example threshold profile (Part 2 Appendix I)

Example Example threshold profile · status EXAMPLE · not used for tier judgment · source: TTAK draft (v0.95)

The numbers in Part 2 Appendix I are not values with an established academic basis. The example threshold profile records these numbers in the Annex D structure and has the status EXAMPLE and is used only for provisional calculation and tool development, never for tier judgments; all values in the tables below are example values.

Tier bands (minimum dimension score) — example

TierTier nameMinimum dimension score
Tier 4Platinum0.95 or higher
Tier 3Gold0.85 or higher, below 0.95
Tier 2Silver0.70 or higher, below 0.85
Tier 1Bronze0.50 or higher, below 0.70
Tier 0UnqualifiedBelow 0.50, or a pass line not met

Tier 0 applies when the minimum dimension score is below 0.50, and when the candidate tier was Tier 1 but a dimension fell short of the Tier 1 pass line, so the result was demoted by one tier.

Per-dimension required pass lines — example

Per-dimension required pass lines — expand table (7 rows)
DimensionTier 1Tier 2Tier 3Tier 4
D1 Completeness0.600.750.850.95
D2 Consistency0.500.700.800.90
D3 Accuracy0.650.800.900.95
D4 Timeliness0.400.600.750.85
D5 Validity0.600.750.850.95
D6 Uniqueness0.600.750.850.95
D7 Machine readability0.800.900.951.00

Dimension weights — example

Dimension weights — expand table (7 rows)
DimensionExample weightAdjustment range
D1 Completeness0.180.10 – 0.25
D2 Consistency0.100.07 – 0.18
D3 Accuracy0.240.17 – 0.32
D4 Timeliness0.100.05 – 0.18
D5 Validity0.130.08 – 0.20
D6 Uniqueness0.120.08 – 0.18
D7 Machine readability0.130.08 – 0.20
Other values — example
ItemExample value
DM-1 evaluation coverage lower bound (DM-1 is not judged with the example threshold profile)0.50
D3-02 (label accuracy) label match criterion: image overlap ratio0.5 or higher
D5-03 dummy value patterns999999, 99999999, 9999, -1, -9, 0000

Purpose-specific criteria

The judgment criteria for the purpose tier are set by the operating guideline. A purpose tier is judged only when an operation-layer profile in registered status (Registered) exists for the use purpose type; for a type without a registered profile, no purpose tier is judged (PROFILE_NOT_REGISTERED). In that case, data prepared for a purpose (Purpose-Ready) is not reached either. There are four profile statuses: Draft, Candidate, Registered and Deprecated.

Measurement before an operating guideline is applied

Measurement and writing the diagnostic report are possible without an operating guideline. In that case the diagnostic tool measures D5-03 (Statistical plausibility) provisionally with the example patterns in Part 2 Appendix I and records the evaluation status as PROVISIONAL, and no tier is judged (not judged: no operating guideline applied).

Re-measurement after an operating guideline is applied

If, after an operating guideline is applied, its D5-03 patterns differ from the example, measure again and issue a new diagnostic report. Reuse an existing diagnostic report as is only when the target version, measurement rules, threshold profile and measurement time are all the same.

The steps for Diagnostic Maturity and tier judgment are in Judgment procedure.

Basis: Part 1 3.20, 3.21, 5.1, 5.5, 5.6 Table 5-3, 7.1, Annex A · Part 2 6, 7.1, 7.3, 9.1, Table 9-3, Annex B.5, Annex D Table D.1, Appendix I Tables I.1–I.4 · Part 3 8.2, Annex C.19

Other paths · Preparing data — Writing the manifest (stage 1) · For agents — What agents read