About this site 한국어

Unofficial explanatory translation of the Korean AI-Ready Data (AIRD) draft standard. The Korean text prevails.

Operating guidelines

Building an operating guideline

Type · ProcedureReading time · about 6 minAdopting and operating organizationsOrganizations that buy or procure data

ContentsContents
  1. What the operating guideline sets and what the standard specifies
  2. Standard-provided and organizational operating guidelines
  3. Structure of the threshold profile
  4. Tier labels and publication requirements
  5. Example threshold profile (Part 2 Appendix I)
  6. Purpose-specific criteria
  7. Without an operating guideline

An operating guideline is a document that holds judgment threshold values and operational matters, built separately from the standard. An organization can adopt the standard-provided operating guideline or build its own.

What the operating guideline sets and what the standard specifies

Tier elements follow the standard; operational elements are set by the operating guideline. Each column is a separate list; items on the same row are not paired.

Set by the operating guideline (operational elements)Specified by the standard (tier elements)
Tier band boundaries in the threshold profileTier scheme Tier 0–4 and tier names (Unqualified · Bronze · Silver · Gold · Platinum) [Part 2 7.1]
Per-dimension required pass lines, dimension weights, and weight adjustment ranges in the threshold profileJudgment procedure: candidate tier from the minimum dimension score → pass line check → demotion by one tier if any dimension falls short [Part 2 6 · 7]
DM-1 evaluation coverage lower bound and indicator parameters (D3-02 label match criterion · D5-03 dummy value patterns) in the threshold profileDefinitions, measurement formulas, and the Diagnostic Maturity decision table for the 16 quality indicators [Part 2 Annex B.5]
Identifier, version, and activation procedure of the threshold profileElement structure of the threshold profile [Part 2 Annex D · Table 9-3]
Operational matters: diagnosis cycle · result validity period · appeal procedure · tool certification [Part 1 7.1]Tier label format Gold (Tier 3, STRUCT) [Part 1 Annex A]
Judgment criteria for purpose tiers · detailed pack structureReadiness states and pack composition [Part 1 5.1 · 5.5]

Standard-provided and organizational operating guidelines

The standard provides an operating guideline. The standard-provided operating guideline is published when the standard is established (expected December 2026). There is more than one guideline publisher. Organizations, institutions, and domains can build operating guidelines independently. [Part 1 3.20 · 3.21 · 7.1]

ApproachWhat the guideline publisher does
Adopt the standard-provided operating guidelineApplies the standard-provided operating guideline as is, and states that guideline’s identifier and version with the tier
Adjust the standard-provided operating guidelineAdjusts the threshold profile and operational matters based on the standard-provided operating guideline, and publishes the adjusted guideline under its own identifier and version
Build its own operating guidelineSets the threshold profile and operational matters directly, and publishes the guideline under its own identifier and version

In every approach, tier elements follow the standard. The same score can yield a different tier under a different operating guideline.

Structure of the threshold profile

The threshold profile (judgment threshold values) is part of the operating guideline. It is a machine-readable file that holds the numbers adjusted during operation, such as tier bands, pass lines, and weights, with an identifier and a version. The operating guideline sets the identifier, version, and activation procedure of the threshold profile, and Part 2 Annex D specifies the structure of its elements.

Threshold profile elements — expand table (10 rows)
ElementObligationValue rangeValue it sets
profileIdRequiredURIProfile identifier
versionRequiredSemVerProfile version
statusRequiredOFFICIAL or EXAMPLEProfile status
digestRequiredSHA-256Hash of the profile file
tierThresholdsRequired4 values in 0.0–1.0Tier bands (Part 2 7.1)
passLinesRequired7 dimensions × 4 tiersPer-dimension required pass lines (7.2)
dimensionWeightsRequired7 values summing to 1.00Dimension weights (6.3)
weightAdjustmentRangeRequiredLower and upper bound per dimensionWeight adjustment range (6.3)
dm1CoverageRequired0.0–1.0DM-1 evaluation coverage lower bound (8.1)
indicatorParametersConditionally requiredObject per indicatorD3-02 image label match criterion · D5-03 dummy value patterns

[Part 2 Annex D Table D.1] · Machine representation: aird-threshold-profile-1.0.schema.json (Part 2 Table 9-3)

Tier labels and publication requirements

Whoever judges and publishes tiers observes the following four requirements.

  • Tier label in the standard format. Write the tier in the form Gold (Tier 3, STRUCT). Always include the data type; do not include Diagnostic Maturity (DM) in the tier label. [Part 1 Annex A]
  • Operating guideline identifier and version alongside. State the identifier and version of the operating guideline applied in the judgment together with the tier.
  • Publication of the operating guideline and threshold profile. Publish the applied operating guideline and threshold profile so anyone can access them.
  • Hash record. Record the identifier, version, and hash of the threshold profile in the diagnostic report. Data users can use the hash to verify the file used in the judgment. [Part 2 9.1]

Example threshold profile (Part 2 Appendix I)

Example Example threshold profile · status EXAMPLE · not used for tier judgment · source: draft standard (TTAK deliberation draft v0.95) [Part 2 Appendix I Tables I.1 – I.4]

The numbers in Part 2 Appendix I are not values with an established academic basis. The example threshold profile is a file that records the Appendix I numbers in the Annex D structure, and its status is EXAMPLE. The example threshold profile is used only for provisional calculation and tool development, not for tier judgment. All values in the tables for tier bands, per-dimension required pass lines, dimension weights, and other numbers are example values.

Tier bands (minimum dimension score) — example

TierTier nameMinimum dimension score
Tier 4Platinum0.95 or higher
Tier 3Gold0.85 or higher, below 0.95
Tier 2Silver0.70 or higher, below 0.85
Tier 1Bronze0.50 or higher, below 0.70
Tier 0UnqualifiedBelow 0.50, or a pass line not met

Tier 0 applies in two cases. First, when the minimum dimension score is below 0.50. Second, when the candidate tier was Tier 1 but a dimension fell short of the Tier 1 pass line, so the result was demoted by one tier. [Part 2 7.3]

Per-dimension required pass lines — example

Per-dimension required pass lines — expand table (7 rows)
DimensionTier 1Tier 2Tier 3Tier 4
D1 Completeness0.600.750.850.95
D2 Consistency0.500.700.800.90
D3 Accuracy0.650.800.900.95
D4 Timeliness0.400.600.750.85
D5 Validity0.600.750.850.95
D6 Uniqueness0.600.750.850.95
D7 Machine readability0.800.900.951.00

Dimension weights — example

Dimension weights — expand table (7 rows)
DimensionExample weightAdjustment range
D1 Completeness0.180.10 – 0.25
D2 Consistency0.100.07 – 0.18
D3 Accuracy0.240.17 – 0.32
D4 Timeliness0.100.05 – 0.18
D5 Validity0.130.08 – 0.20
D6 Uniqueness0.120.08 – 0.18
D7 Machine readability0.130.08 – 0.20

Other values — example

ItemExample value
DM-1 evaluation coverage lower bound (DM-1 is not judged with the example threshold profile)0.50
D3-02 image overlap ratio0.5 or higher
D5-03 dummy value patterns999999, 99999999, 9999, -1, -9, 0000

Purpose-specific criteria

The judgment criteria for the purpose tier are set by the operating guideline. A purpose tier is judged only when an operation-layer profile in registered status (Registered) exists for the use purpose type. For a type without a registered profile, no purpose tier is judged (PROFILE_NOT_REGISTERED). In that case, data prepared for a purpose (Purpose-Ready) is not reached either. There are four profile statuses: Draft · Candidate · Registered · Deprecated. [Part 1 5.6 · Table 5-3 · Part 3 8.2 · Annex C.19]

Without an operating guideline

Measurement and writing the diagnostic report are possible without an operating guideline. The diagnostic tool measures D5-03 (Statistical plausibility) provisionally with the example patterns in Part 2 Appendix I and records the evaluation status as PROVISIONAL. Results without an applied operating guideline get no tier judgment (not judged: no operating guideline applied). After an operating guideline is applied, if its D5-03 patterns differ from the example, measure again and issue a new diagnostic report. Reuse an existing diagnostic report as is only when the target version, measurement rules, threshold profile, and measurement time are all the same. The steps for Diagnostic Maturity and tier judgment are in Judgment procedure.

Other paths · Preparing data — Writing the manifest (stage 1) · For agents — What agents read

Last updated · 2026-10-07Report an error